2013 Nissan Juke
Mileage
56,735
Service Date
5/29/2024
Services Performed
- Checked under hood fluid levels
- Performed visual inspection of ac system found ac compressor clutch wet with refrigerant, this means front seal is leaking ac system would need to be replaced
- Replaced ac compressor assembly recheck ok
- Flushed entire ac condenser and replaced receiver drier attached to ac condenser recheck ok
- Replaced expansion valve recheck ok
- Check of system pressures, vent temperature, vent operation, condenser for debris, compressor operation, condition of drive belt and lines. Evacuate and recharge system to proper capacity with R134A refrigerant. Leak test system, add oil and dye as needed. Performed ac service recovered .600 lbs r134a, replaced both schrader valves, vacuum system down 20 minutes, charged .899 lbs r134a. Pressure low side 28, high 170 vent temperature 42’f dye checked no leaks present recheck OK
- Fronts 35psi Rears 35psi
Gary D. gave our service a 5 star review on 5/29/2024